620.24 Branch Circuit for Hoistway Pit Lighting and Receptacle (s). Locate per layout. In addition to this general discussion section refer to the following applicable sections: • Section 14210 – Electric Traction Elevators Machine room/space or control room/space lights, HVAC, elevator car lights, & pit lights must also be on generator (reference Note 3 below). Locate per layout. Each of these performs a different function, and the wiring mandates vary accordingly. 10. SBC 3016.3 and ASME, 8.4. … Pit light and GFI receptacle located at the bottom of the hoistway as per the drawings 4. The requirements for GFCI protection in dwelling units have expanded to include 250-volt, single-phase receptacles that are 50 amperes or less, in addition to the existing requirements for all 125-volt receptacles. *M. If elevator is to run on emergency power – it must be tested on emergency power. 9. 618-244-2314; sales@phoenixmodularelevator.com ... → A ladder so the technician can descend into the pit. Location. All to be NEMA 4 for wet application. All elevator hoistways must be equipped with a sump pit located at the rear of the elevator pit. (GFCI requirements and prohibitions are found in Sections 620.23, 620.24 and 620.85.) Provide a new GFCI receptacle outside next to the new outdoor condensing unit. Separate branch circuits are required for the pit lighting and the receptacles. Enter the email address you signed up with and we'll email you a reset link. Provide a dedicated 20A normal circuit for GFCI receptacle(s) and required lighting fixtures for wet locations. – Provide a 110V single-phase lockable disconnect (for hoistway pit lighting) in the machinery space accessible from outside of the hoistway with feeder branch wiring Provide 10 ftc of lighting at the pit floor or pit platform. ), a duplex 15A 120-volt receptacle in pit with ground- fault circuit protection and a 15A 120-volt Non GFCI receptacle for the sump pump. Elevator Electrical Requirements By General Contractor/Owner ... 120V 15 Amp Fused Disconnect or Circuit Breaker, as outlined, for cab lighting. 3. According to these rules, at least three branch circuits are required. These elevator codes specify certain requirements of the elevator and machine room for safety, including the design of the machine room and use of smoke detectors. 2. The 2012 IECC permits fixtures used for the following purposes to be treated as exempt from inclusion in interior lighting power totals. Learn more here. The elevator pit lighting is not permitted to be GFCI-protected. you need two circuits. However, due to the presence of numerous and varied types of elevator hoistway equipment, conduit runs in the elevator hoistway must be limited. 15-20 Amp 120 volt Receptacle Requirements: Within 20 feet of the pool wall, For underwater pool lights, power to storable pools, constructions sites effective 1974 ... (lighting and submersible equipment), cord and plug-connected fountains, Lighting ... elevator car tops, elevator pits. mount within 48" of elevator pit floor in accordance to state elevator code requirements. 19. 2,788. nema 4 rated elevator pit light fixture. A sump pump and sump pump hole with cover is recommended in the elevator pit where water seepage is encountered. PIT SWITCHES with GFCI OUTLETS and WORK LIGHT Model PWLG ... 2-Gang box and cover • Duplex GFCI outlet • 15A 125VAC • Light switch • Single-Pole • 1NO, 10A 220VAC, 20A 125VAC • Light bulb socket: • Medium base • 250V 660W The Hydraulic Elevators will differ from the traction elevator in the following main components: Machine/drive system. Light switch shall be accessible from pit access door. Learn More Estimate the life expectancy of your elevator equipment. 18. Provide duplex electrical receptacle near controller and whatever additional electrical receptacles are needed to meet ANSI 17.1 and N.E.C. Paint the pit floor and sump with a “battleship gray” waterproof paint, made for the purpose. 8. The switch shall be near the stop switch. 2). Luminaires must be lensed or equipped with wire guards to protect the lamps. Learn More Learn 10 easy money saving tips for elevator contracts. 5.11.10 Any time an existing well is identified as not meeting the requirements of this Section, the well head shall be brought into compliance unless otherwise approved by the Department. Informational Note No. ASME A17.1 2.2.5.1 NFPA 70 620.24 Yes No 26)Provide a 120-volt, 20-amp, GFI receptacle in pit. 2. As a minimum, three separate 120 Volt circuits shall be provided for each of the following: elevator car lighting, elevator pit and hoistway lighting and receptacles, and car camera. locate light switch near top of ladder to be accessible from pit access door. switch for each elevator, with feeder wiring to each controller for car lights. A minimum of two 2 tube, 4’, T8 LED lighting fixtures shall be installed for the elevator machine room lighting. Provide proper protection against bulb breakage/damage. 3). 1.3 Design criteria NOTE: Virtually every transit escalator installation will require a remote machine room to accommodate the controller, drives and related equipment to operate the escalator. A G.F.I. ... and other requirements. ASME A17.1/CSA B44 requires that all elevator pits for elevators that have Firefighters’ Emergency Operation, be provided with a drain or sump pump. NEW & ALTERED EQUIPMENT ASME A17.1-2016/CSA B44-16 IBC - 2018 NFPA 5000 – 2018 (BCSC) NFPA 101 – 2018(LSC) (b) conformance with some of the requirements in ASME A17.1/CSA B44 and for systems, Wells permitted prior to the effective date of these Regulations are exempt. the pit or hoistway for the purposes of supplying pit lighting and receptacles, heat and smoke detectors, and sump pumps. Elevator Pit: Check stop switch, access, sump cover, car buffers, lighting, service receptacles, car guides and housekeeping. Communication Lines for the elevator car A17.1/B44 Yes They are as follows: Main Power – 10/3 with Ground (min. Maintenance of pit and hoistway 120 volt circuits for lighting and receptacles. Provide electrical wiring and conduit between the new wall-mounted indoor unit and the ground-mounted outdoor condensing unit. Somewhere in this space or room you must see at least one or more disconnects. Figure 1. All Models are designed to meet ANSI A17.1 Rules 106.1f and 210.2e/2g Elevator Safety Code Requirements. receptacle is required if a sump pump is furnished. If all the hazards in the elevator pit can be eliminated [prior to entry], the pit can be reclassified as a non-permit space. The switch shall be near the stop switch. Enter the email address you signed up with and we'll email you a reset link. position light to provide 10 foot candles at floor level/base of pit ladder. 5050-A Business Drive Morehead City, NC 28557 877-720-0075 toll free . NEMA 4 : All electrical equipment, located less than 1225 mm (48 in.) above the pit floor, shall: Be weatherproof (NEMA 4). Have wiring identified for use in wet locations in accordance with the requirements in NFPA 70. GFI Receptacles: GFI receptacles shall be required in all elevator machine rooms, machinery spaces and elevator pit areas. The light shall be guarded per ASME A17.1, Section 2.2.5. Fig. 18. See Director’s Rule 7-2014/SFD Administrative Rule 9.06.14 for sprinkler requirements related to elevators. Elevator pits with grade beams. Special care, From that statement, I would read it as you need a seperate circuit for each. (762mm) and a minimum height of 6 ft (1.83m) for machine rooms and a minimum height of 30 in. Elevators shall comply Seismic Design Category D for seismic requirements. 2. Again the light cannot be installed on the load side of a GFCI. Replace existing outlets with GFCI type. Date: 2-2-2015, revision to document dated 4-15-2013. This department recognizes the need for non-elevator personnel to occasionally maintain or service other equipment or devices installed inside an elevator hoistway that are not a part of the conveyance. 3. One (1) 220V 30 Amp Fused Disconnect, as outlined, below for main ... please call Southeastern Elevator @ (252) 725-1235. D. Separate disconnect for balustrade lighting, comb plate heater and pit/truss heaters. (B) Be self-closing. d. Suitable light and convenience outlets in machine room with light switches located within 18 inches of lock jamb side of machine room door. (762mm) for other spaces specified in Sections 3011 (e) (2) and 3011 (e) (3). Maintenance of pit and hoistway 120 volt circuits for lighting and receptacles. A G.F.I. 618-244-2314; sales@phoenixmodularelevator.com ... → A ladder so the technician can descend into the pit. 4-Jan-19 . #2. NEC, 620-24 ... 26 80 00 - Elevator Electrical Requirements Last modified by: Prasad, Sarthak Company: All work must be per National Electric Code, ASME A17.1 and any local codes. Lighting cannot be on the load side of GFCI. All Models are designed to meet ANSI A17.1 Rules 106.1f and 210.2e/2g Elevator Safety Code Requirements. A separate branch circuit shall supply the hoistway pit lighting and GFCI receptacle(s). 10. 5. • For lighting and GFCI receptacles: 120 volts, 1 phase, 3 wire, 60 Hz terminating in the escalator truss. Elevator Safety Program PO Box 14470 Salem, OR 97309 Tel: (503) 373-1298 Fax: (503) 378-4101 December 13, 1999 ELEVATOR SAFETY PROGRAM CODE INTERPRETATION ... the pit or hoistway for the purposes of supplying pit lighting and receptacles, heat and smoke detectors, and sump pumps. Separate phone line to elevator controller. Light, switch and convenience outlet in elevator pit, light switch accessible from lower landing opening. Indirect acting (suspended) hydraulic system in case of using Roped Hydraulic elevator. The guidelines for safety code requirements specified in the current ASME A17.1 Code for Elevators. Lights and convenience outlets in elevator pits shall be installed to comply with the requirements of CCR, Title 24, Part 3, Article 620. Some states, such as California, even have their own elevator codes. 9. Codes. Provide 10ftc of lighting at the pit floor or pit platform. A pit light with switch if required by local code. 2: See 620.6 for ground-fault circuit-interrupter requirements. The main elevator power shall be 480 Vac, three phase, 60 Hertz. UFC 3-490-06 8 June 2018 Change 1, 13 January 2021 UNIFIED FACILITIES CRITERIA (UFC) SUMMARY SHEET Document: UFC 3-490-06: Elevators Superseding: NAVFAC ITG 2013-01, NAVFAC Elevator Design Criteria Description: This UFC 3-490-06 incorporates tri-service requirements into one unified document and provides design and construction requirements … Provide a duplex electrical receptacle (3 ft. above finished floor), light and switch in the pit. Traction Elevators --- safety plank, counterweight and car buffers, governor and tail sheave. (Mo. At least one duplex receptacle must be provided in each elevator pit. The elevator pit lighting is not permitted to be GFCI-protected. The reason for two branch circuits is safety-driven. While working in an elevator pit using portable tools, it is possible to trip the upstream overcurrent protective device. NEC Article 620 covers elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. C.1.4 ELEVATOR PIT REQUIREMENTS 1. All wiring in elevator machine room shall be enclosed in electrical conduit. Pit Lighting A pit light and GFI duplex receptacle, supplied by the General Contractor, are required in the pit of your Elvoron LU/LA for use by the mechanic during his maintenance visit. – Per the latest National Electrical Code, all receptacles installed in machine rooms, machinery and control spaces, and pits must have Ground Fault Circuit Interrupter Protection (GFCI). 2). BPA, The Code is a minimum standard, you can provide more lighting than required, just not less. N. ASME A17.1 [2.27.1.1]: General Contractor to provide dedicated analog telephone line (1 for each Interior elevator cab panels that utilize adhesives for mounting/installation shall not be permitted. 2. Pit light with guard (ten foot candles min. Request further emergency phone installation design requirements from Engineering Services. 2. IBC 2003 Section 1007.4 Elevators : indicates, “An elevator to be considered part of an accessible means of egress shall comply with the emergency operation and signaling device requirements of Section 2.27 of ASME A17.1 Standby power shall be provided in accordance with section 2702 and 3003. When a structure’s foundation is separated from the elevator pit as shown above, the waterproofing is able to fully wrap the elevator pit using typical details. Cords for pit pumps are to be hard usage oil resistant type, shall not exceed exposed lengths of 6 feet, and shall meet the requirements of NEC 70 620.21(A)(1)(d). Where two or more cars share a common pit, all luminaires shall activate when any associated light switch is turned on. This debate is whether the elevator inspector will enforce the sprinkler in the elevator pit? Mar 29, 2017. Coordinate location with elevator contractor. (vii) Add the definition platform guard (toe guard or apron) between pit elevator and plunger (ram) to read as follows: Platform Guard (Toe Guard or Apron).- A section of sheet metal the full width of the door opening, securely 2. 1- Machine / Drive system: The lift car shall be driven by one of the following methods: Direct acting. ASME A17.1, Section 2.2.5, National Electrical Code, Rule 620-85 4. First, you'll need to install lighting in the elevator equipment room (Photo 1) and shaft pit (Photo 2). NEC Article 620 covers elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. This UFC was developed to provide the authority having jurisdiction (AHJ) with consistent Most elevator pits contain at least mechanical and electrical hazards. Convenience outlet in machine room. receptacle installed in pits, in hoistways, on elevator car tops, and in escalator and moving walk wellways shall be of the ground-fault circuit-interrupter type. Provide continuous, non- slip, horizontal rungs every 12” for the full height of the pit ladder. The light switch in the pit must be mounted 42 in. 8. Provide continuous, non -slip, horizontal rungs every 12” for the full height of the pit ladder. All non-elevator-related piping and equipment shall be prohibited from entering or passing through the pit. Drains and pumps shall comply with applicable plumbing and electric codes. and Pits. 9. Remove existing light fixtures to be relocated and rewired. Messages. The Department may impose these requirements upon the reclassification of any well. Title: Any 120 Volt elevator control circuits shall be provided from the Per NFPA 70 620.24 (A) Light and switch in elevator machine room, with switch located adjacent to access door. Receptacles shall be manually reset type 4. 680.23 (mechanical room) and 680.24 (pit) both state they require a seperate branch circuit for the lights and recep in each of those locations. to elevator technology. Oct 17, 2009. ____ - REQUIRED PIT LIGHT---The required pit lighting shall not be connected to the load side of the GFCI per NFPA 70 620-24. Hoistway overhead lighting fixture, illumination and receptacle requirements per conveyance shop drawings / submittals, NEC and ASME Codes (where applicable) NOTE: (SEE NEXT PAGE) As of January 1, 2020: Requirements for Clearances Between Hoistway Doors and Landing Sills will be enforced as written in ASME A17.1 – 2016 (5.3.1.7.2). Many localities adopt national or state building codes as their standard . The most NEC Article 620: Elevators, Part 1 by David Herres photos by Judith Howcroft Continued 6″) Pigtail connected to house 20 Amp dedicated circuit. Elevators can be built in homes and businesses, but all need to follow the elevator codes specified by ASME A17.1. Ladder shall be provided and extend 48" above the pit access floor or as instructed by the consultant. Elevator Hoistway Lighting. 10. C.1.4 ELEVATOR PIT REQUIREMENTS 1. The most NEC Article 620: Elevators, Part 1 by David Herres photos by Judith Howcroft Continued In contrast to the lighting, these receptacles must be connected to GFCI devices. Locate per layout. 10. This section requires each 125V, single-phase, 15/20A receptacle installed in pits, hoistways, on the cars of elevators and dumbwaiters associated with wind turbine tower elevators, on the platforms or in the runways and machinery spaces of platform lifts and stairway chairlifts, and in escalator and moving walk wellways to be of the GFCI type. There are still critical reasons why all elevators have pits. Before. Coordinate location with elevator contractor. Where a fire service access elevator is required, a 1-hour fire-rated fire service access elevator lobby with direct access from the fire service access elevator is not required if the fire service access elevator opens into an exit access corridor that is no less than 6 feet wide for its entire length and is at least 150 square feet with the exception of door openings, and has a minimum 1 … → Electrical wiring including a light and outlet for working purposes. Find the latest information on elevator codes, laws and safety standards. Oct 17, 2009. Provide a duplex electrical receptacle, light and switch within 18" of lock-side of jamb in machine room. Provide one GFCI type duplex utility receptacle near each elevator hoist machine. – Provide adequate lighting and receptacle in machine room. → Electrical wiring including a light and outlet for working purposes. #2. Coordinate location with elevator contractor. A pit light with switch and a GFI duplex receptacle in accordance with National Electric Code. A sump pump and sump pump hole with cover is recommended in the elevator pit where water seepage is encountered. Now. 1: See ASME A17.1-2016/CSA B44-16, Safety Code for Elevators and Escalators, for illumination levels. Pit light and elevator stop switches located adjacent to pit ladder; Drain or sump pump with cover. Furnish properly located light switch and GFCI duplex outlet near pit entry. 10. Light and GFI receptacle located on the shaft ceiling as per the drawings 3. The performance language used in the codes results in a multitude of different, and often conflicting, interpretations. Light must have an external guard and be located at a point where illumination on the pit ladder base is no less than 10 foot candles. 8. 19. e. Convenience outlet and light fixture in pit with switch located adjacent to the access door. Convenience outlet in machine room. A G.F.I. 2. Ties directly into room light and outlet. It seems very cut in dry that per 2013 NFPA – 8.15.5.2 that the sprinklers not required. 3. GFCI convenience outlet shall be installed in the pit, higher than 24 inches above finished floor. operational requirements for elevator systems and for the building systems that interface with the elevator microprocessor controllers. BPA, The Code is a minimum standard, you can provide more lighting than required, just not less. Door Protection Elevators are protected by a several types of door reopening Elevators are protected by a several types of door reopening devices: Infrared Safety Curtains Infrared Safety Curtains – These devices scan the areas These devices scan the areas adjacent to the elevator adjacent to the elevator door(s) and automatically reopen ) and automatically reopen 1. C.1.4 ELEVATOR PIT REQUIREMENTS 1. Messages. ☐ Verify required branch circuit for hoist way pit lighting and receptacle ☐ Verify for required receptacle and light switch provisions in machine rooms and pits Note: This checklist provides a guideline of topics that may be reviewed during plan review. The elevator pit shall have a separate branch circuit supplying pit lighting and receptacle(s) and another for the pit sump pump. One (1) Fixture (with a protective cover over bulb) with a wall switch. 6. receptacle is required if a sump pump is furnished. ASME A17.1 – 2004 Safety Code for Elevators and Escalators seems only to tell you what to do if there is a fire sprinkler in the elevator pit. Elevator Industry Resource Directory. shall coordinate the electrical requirements as well as the code requirements for the pit, overhead clearance, shaft ventilation, pit ladder, light (with switch adjacent to ladder) and electrical duplex 120 VAC outlet in pit, equipment room and phone in cab. The light shall be guarded per ASME A17.1 - 2.2.5. Light switch shall be accessible from pit access door. Disconnect not required, as this can land directly into the controller. ____ - GFCI TYPE RECEPTACLE---A GFCI type receptacle shall be provided in pits and on car tops per NFPA 70 Rule 620-85. i.e. to elevator technology. A pit light with switch if required by local code. Therefore, it is not permissible to use the Engrave the receptacle cover to read "FOR EMERGENCY PHONE USE ONLY". One is required for elevator car lighting and receptacles, one for machine/control room lighting and receptacles and one for hoistway pit lighting and receptacles. A G.F.I. – Provide a light and receptacle in elevator pit. In addition to this general discussion section refer to the following applicable sections: Section 14210 – Electric Traction Elevators The pit drainage shall be designed to remove a minimum capacity of 3,000 gallons per hour (or 50 GPM) per elevator car. Elevator pit receptacles circuit is likewise. 17. This requires the entire shaft to be lit to min 1 foot-candle measured on top of the car when firefighter's emergency operation is active. Pit lighting & receptacles1 NFPA 70 Yes Wire runs restricted to the extent necessary to connect the switches, luminaires, and receptacles. Suitable 110V service in the hoistway, midway of Lighting Required in Elevator Pits: LED light fixtures shall be required in all elevator pits. A pit light with switch if required by local code. Provide car top inspection station complete with light and GFCI protected outlet. We've just encountered the requirement for this in the 2012 International Building Code Section 3007.6.2. Provide new vertically mounted light fixture in elevator pit and light switch. COMMERCIAL ELEVATOR / ESCALATOR / DUMBWAITER / VERTICAL PLATFORM LIFT / INCLINED PLATFORM LIFT / MATERIAL LIFT / LULA / “CONVEYANCE” PLAN REVIEW REQUIREMENTS ADOPTED CODES EFFECTIVE 1/1/2022: • ASME A17.1 2019 Safety Code for Elevators and Escalators • ASME A18.1 2017 Safety Standards for Vertical Platform Lifts and Stairway Chairlifts Terminate phone line on side of each elevator controller in a 2" x 4" electrical box with cover plate. For lighting and ground fault circuit interrupter (GFCI) receptacles: 120 V, one-phase, three-wire, 60 Hz terminating at the escalator controller location. PIT SWITCHES with GFCI OUTLETS and WORK LIGHT Model PWLG ... 2-Gang box and cover • Duplex GFCI outlet • 15A 125VAC • Light switch • Single-Pole • 1NO, 10A 220VAC, 20A 125VAC • Light bulb socket: • Medium base • 250V 660W ASME A17.1 2.2.5.1 NFPA 70 620.24 Yes No 26)Provide a 120-volt, 20-amp, GFI receptacle in pit. NOTE: It is important to check your state building codes as well, as they may have further elevator code requirements. Learn More Consultants ____ - SPRINKLER IN HOISTWAY Site element diagram. the code requirements for the pit, overhead clearance, shaft ventilation, pit ladder, light (with switch adjacent to ladder) and electrical duplex 120 VAC outlet in pit, equipment room and phone in cab. 3. (A) Separate Branch Circuit. Prior to installation, barricades must be in place at all hoistway openings. Safety system. Elevator Litigation / Attorneys. 1. 18. GENERAL REQUIERMENTS FOR ALL ELEVATORS: Pit Sump Pump: Dedicated circuit and devices as required by load. 8. 9. This is the area within the hoistway beneath the car, and there are occa-sions when elevator technicians have Informational Note No. Coordinate location with elevator contractor. At least one 125-volt, single-phase, 15- or 20-ampere duplex receptacle shall be provided in the hoistway pit. At least one duplex receptacle must be provided in each elevator pit. – All electrical upgrades - Pit lighting and GFCI outlet - Machine Room Lighting and GFCI outlet - Main line disconnect - 110 cab light disconnect - Alarm system for the elevator in the machine room, hoist way, hallways and monitoring panel And the connections brought to the machine room. The light switch for the equipment room must be adjacent to the entrance door on the latch side. 25) Provide a guarded light in the pit with minimum of 10 foot-candle at floor level. The separate branch circuits for pit lighting and duplex outlet can be provided other than in the elevator machine/control room. Mar 29, 2017. Install a pit drain, if the elevator is provided with firefighter's emergency operation Each pit receptacle shall be a GFCI type (except for sump pumps) Permanent lighting shall be installed in the pit, with a illumination of not less than 1001x at the pit floor The pit light shall be provided with a … Lighting cannot be on the load side of GFCI. Drain / sump pump shall not be connected directly to a sewer or discharged onto the ground. the code requirements for the pit, overhead clearance, shaft ventilation, pit ladder, light (with switch adjacent to ladder) and electrical duplex 120 VAC outlet in pit, equipment room and phone in cab. The specific requirement for 'incandescent' is probably a hold over from the … Machine room power (light and outlet): 120 volt, 20 amp dedicated circuit. Light and switch in elevator room, with switch located adjacent to access door. GFI duplex receptacle is required in the pit for use by the mechanic during his maintenance visit. MATRIX OF ELEVATOR & ESCALATOR RELATED REQUIREMENTS IN THE MODEL CODES vs. ASME A17.1/CSA B44 & A17.3 . Title: Suitable 110V service connected to terminals in elevator controller for car The Empire State. From the `12 IRC, Section M1305.1.3.1 - Electrical requirements: "A luminaire controlled by a switch located at the required passageway opening and a receptacle outlet shall be installed at or near the appliance location in accordance with Chapter 39. " Electric Receptacles (1988) (in good condition) *Operating Controls Identified (brail and raised numbers) *Pit Light Switch (in good condition) *Safety Parts and Plates (in good condition) *Elevator Stop Switch & Location (in good condition) Minimum Requirements for Elevator Inspections per A17.2 Sections 1 - 6 One (1) GFI Outlet. Hoistway power (pit light and outlet): Two 120 volt, 20 amp dedicated circuits. The Empire State. A separate branch circuit shall supply the hoistway pit lighting and receptacle (s). Turn the light on and you must see at least one 125-volt, single-phase, GFCI duplex receptacle. Page 5 of 165. Install light to clear elevator car. Habitable space below hoistway will require the pit to B)Elevator pit lighting doesn't need dedicated circuit. 1.3. CAB Light Power – 12/2 with Ground (min. One (1) 220V 30 Amp Fused Disconnect, as outlined, below for main ... please call Southeastern Elevator @ (252) 725-1235. 5050-A Business Drive Morehead City, NC 28557 877-720-0075 toll free . 6″) Pigtail connected to house 30 Amp dedicated circuit. 25) Provide a guarded light in the pit with minimum of 10 foot-candle at floor level. Accessing Elevator Hoistways. A)Elevator pit lighting circuit is independent. The disconnect for the car lighting/receptacle/ventilation circuit must be located in this area. (g) Stop Switch in Pits. Our directories are updated monthly and include website links to help you quickly find your elevator code authority for your state ... ADA Elevator Code Requirements. Each of these performs a different function, and the wiring mandates vary accordingly. There has to be a potential or actual hazard present in the elevator pit in order for it to be classified as a permit-required confined space. WoodrowJWeen (Electrical) (OP) 1 Apr 16 18:19. so don't connect to any other lightings installed at near space out of pit. above the seal plate, adjacent to the ladder. Allow 8″ for recessed elevator pit in slab; Allow for proper overhead clearance (96″ minimum) Size closets to match standard elevator shaft requirements (60″ x 60″) This change helps protect against shocks and electrocutions for higher voltage receptacles. Submittals A. attendant and shall meet the requirements of rules 211.4 and 211.5(c) of this reference standard. Another location that requires a separate branch circuit for lighting and receptacle(s) is the hoistway pit. receptacle is required if a sump pump is furnished. The specific requirement for 'incandescent' is probably a hold over from the … Disconnect size to suit elevator contractor’s equipment requirements. Password requirements: 6 to 30 characters long; ASCII characters only (characters found on a standard US keyboard); must contain at least 4 different symbols; at least 1 number, 1 uppercase and 1 lowercase letter; not based on your username or email address. Installation or maintenance of pit sump pump or drain. Pit lighting and GFI receptacle: Dedicated 20A normal circuit for GFI receptacle(s) and required lighting fixtures.